Pellet for LA-ICP-MS and LIBS application /// The principle behind LA-ICP-MS (Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry) involves a laser beam removing (ablating) material from a sample and analysing its chemical composition in a mass spectrometer /// LIBS (Laser-Induced Breakdown Spectroscopy) uses a laser beam to interact with the sample. Due to the extreme heat of the laser (10,000 K and more) a plasma is formed. A plasma is a cloud of ions (charged atoms) and electrons (negatively charged particles). When this plasma collapses it emits light. Light is a mixture of different wavelengths. This light is then transferred through a fiberoptic cable to a spectrometer, which can precisely split the light into its respective wavelengths. The working principle of the LIBS-spectrometer is similar to a prism as it disperses the incomming light. Each element has several characteristic wavelengths. A detector is able to attribute an intensity to each of them.
Contents
Analyte
CAS Number
Concentration
Unit
Additional information
Method
Na2O
2,58 ± 0,05
g/100g
Al2O3
18,61 ± 0,14
g/100g
SiO2
65,02 ± 0,18
g/100g
P2O5
0,024 ± 0,01
g/100g
K2O
12,81 ± 0,14
g/100g
CaO
0,11 ± 0,02
g/100g
TiO2
0,02 ± 0,01
g/100g
MnO
0,005 ± 0,001
g/100g
Fe2O3(T)
0,09 ± 0,03
g/100g
Lithium (Li)
[7439-93-2]
8,5 ± 1,7
µg/g
Beryllium (Be)
[7440-41-7]
1 ± 0,11
µg/g
Scandium (Sc)
[7440-20-2]
0,05 ± 0,01
µg/g
Vanadium (V)
[7440-62-2]
0,5 ± 0,2
µg/g
Chromium (Cr)
[7440-47-3]
5 ± 1,8
µg/g
Cobalt (Co)
[7440-48-4]
14 ± 1,5
µg/g
Nickel (Ni)
[7440-02-0]
1,5 ± 0,5
µg/g
Copper (Cu)
[7440-50-8]
2 ± 1
µg/g
Zinc (Zn)
[7440-66-6]
10 ± 3
µg/g
Gallium (Ga)
[7440-55-3]
23 ± 2,5
µg/g
Rubidium (Rb)
[7440-17-7]
860 ± 50
µg/g
Strontium (Sr)
[7440-24-6]
39 ± 4
µg/g
Yttrium (Y)
[7440-65-5]
0,5 ± 0,1
µg/g
Zirconium (Zr)
[7440-67-7]
0,7 ± 0,2
µg/g
Molybdenum (Mo)
[7439-98-7]
0,25 ± 0,1
µg/g
Tin (Sn)
[7440-31-5]
0,3 ± 0,1
µg/g
Antimony (Sb)
[7440-36-0]
0,45 ± 0,08
µg/g
Caesium (Cs)
[7440-46-2]
7 ± 0,8
µg/g
Barium (Ba)
[7440-39-3]
200 ± 16
µg/g
Lanthanum (La)
[7439-91-0]
0,95 ± 0,12
µg/g
Cerium (Ce)
[7440-45-1]
1 ± 0,1
µg/g
Praseodymium (Pr)
[7440-10-0]
0,09 ± 0,1
µg/g
Neodymium (Nd)
[7440-00-8]
0,3 ± 0,08
µg/g
Samarium (Sm)
[7440-19-9]
0,05 ± 0,02
µg/g
Europium (Eu)
[7440-53-1]
0,45 ± 0,04
µg/g
Gadolinium (Gd)
[7440-54-2]
0,06 ± 0,01
µg/g
Terbium (Tb)
[7440-27-9]
0,01 ± 0,005
µg/g
Dysprosium (Dy)
[7429-91-6]
0,06 ± 0,01
µg/g
Holmium (Ho)
[7440-60-0]
0,012 ± 0,004
µg/g
Erbium (Er)
[7440-52-0]
0,04 ± 0,01
µg/g
Thulium (Tm)
[7440-30-4]
0,006 ± 0,003
µg/g
Ytterbium (Yb)
[7440-64-4]
0,04 ± 0,02
µg/g
Lutetium (Lu)
[7439-94-3]
0,006 ± 0,002
µg/g
Tantalum (Ta)
[7440-25-7]
0,25 ± 0,04
µg/g
Tungsten (W)
[7440-33-7]
120 ± 15
µg/g
Lead (Pb)
[7439-92-1]
240 ± 20
µg/g
Uranium (U)
[7440-61-1]
0,15 ± 0,05
µg/g
Miscellaneous
Certificate of Analysis (specimen)
Reference Material CoA specimen: for the current lot, please contact your customer service representative at info@labmix24.com
Product data sheet
View all available product details e.g. description, analytes/parameters, CAS Number, concentrations/values, sales unit/product format, method, source, transport information