Item no.
GEO-GBM913-2
CAS Number
Unit
each
Shipment details
No Dangerous Good /not restricted
| Analyte | Structure formula | CAS Number | Concentration | Unit | Additional information | Method |
|---|---|---|---|---|---|---|
Nickel (Ni)
|
[7440-02-0] | 0,0004 | % | Certified value | ||
Copper (Cu)
|
[7440-50-8] | 0,0011 | % | Certified value | ||
Zinc (Zn)
|
[7440-66-6] | 0,0009 | % | Certified value | ||
Lead
|
[7439-92-1] | 0,0017 | % | Certified value | ||
Arsenic (As)
|
[7440-38-2] | 0,0022 | % | Certified value | ||
Cobalt (Co)
|
[7440-48-4] | 0,0002 | % | Certified value | ||
Silver (Ag)
|
[7440-22-4] | 0,0000001 | % | Certified value | ||
Nickel (Ni)
|
[7440-02-0] | 0,0005 | % | Certified value | Partial Digest (AR etc.) | |
Copper (Cu)
|
[7440-50-8] | 0,0009 | % | Certified value | Partial Digest (AR etc.) | |
Zinc (Zn)
|
[7440-66-6] | 0,0007 | % | Certified value | Partial Digest (AR etc.) | |
Lead
|
[7439-92-1] | 0,0013 | % | Certified value | Partial Digest (AR etc.) | |
Arsenic (As)
|
[7440-38-2] | 0,001 | % | Certified value | Partial Digest (AR etc.) | |
Cobalt (Co)
|
[7440-48-4] | 0,0003 | % | Certified value | Partial Digest (AR etc.) | |
Silver (Ag)
|
[7440-22-4] | 0,00005 | % | Certified value | Partial Digest (AR etc.) | |
Antimony (Sb)
|
[7440-36-0] | 0,000028 | % | Single analysis only - Not certified | Neutron activation analyses | |
Arsenic (As)
|
[7440-38-2] | 0,00237 | % | Single analysis only - Not certified | Neutron activation analyses | |
Barium (Ba)
|
[7440-39-3] | 0,00497 | % | Single analysis only - Not certified | Neutron activation analyses | |
Bromine (Br)
|
[7726-95-6] | 0,000424 | % | Single analysis only - Not certified | Neutron activation analyses | |
Cadmium (Cd)
|
[7440-43-9] | <0,000215 | % | Single analysis only - Not certified | Neutron activation analyses | |
Cerium (Ce)
|
[7440-45-1] | 0,00331 | % | Single analysis only - Not certified | Neutron activation analyses | |
Caesium (Cs)
|
[7440-46-2] | 0,000038 | % | Single analysis only - Not certified | Neutron activation analyses | |
Chromium (Cr)
|
[7440-47-3] | 0,0153 | % | Single analysis only - Not certified | Neutron activation analyses | |
Cobalt (Co)
|
[7440-48-4] | 0,00013 | % | Single analysis only - Not certified | Neutron activation analyses | |
Gold (Au)
|
[7440-57-5] | <0,000106 | % | Single analysis only - Not certified | Neutron activation analyses | |
Hafnium (Hf)
|
[7440-58-6] | 0,00145 | % | Single analysis only - Not certified | Neutron activation analyses | |
Iridium (Ir)
|
[7439-88-5] | <0,000002 | % | Single analysis only - Not certified | Neutron activation analyses | |
Iron (Fe)
|
[7439-89-6] | 18,2 | % | Single analysis only - Not certified | Neutron activation analyses | |
Lanthanum (La)
|
[7439-91-0] | 0,000633 | % | Single analysis only - Not certified | Neutron activation analyses | |
Lutetium (Lu)
|
[7439-94-3] | 0,000022 | % | Single analysis only - Not certified | Neutron activation analyses | |
Molybdenum (Mo)
|
[7439-98-7] | 0,000681 | % | Single analysis only - Not certified | Neutron activation analyses | |
Nickel (Ni)
|
[7440-02-0] | <0,001 | % | Single analysis only - Not certified | Neutron activation analyses | |
Rubidium (Rb)
|
[7440-17-7] | 0,000953 | % | Single analysis only - Not certified | Neutron activation analyses | |
Samarium (Sm)
|
[7440-19-9] | 0,000026 | % | Single analysis only - Not certified | Neutron activation analyses | |
Scandium (Sc)
|
[7440-20-2] | 0,00138 | % | Single analysis only - Not certified | Neutron activation analyses | |
Selenium (Se)
|
[7782-49-2] | <0,000252 | % | Single analysis only - Not certified | Neutron activation analyses | |
Sodium (Na)
|
[7440-23-5] | 0,1 | % | Single analysis only - Not certified | Neutron activation analyses | |
Tantalum (Ta)
|
[7440-25-7] | 0,000383 | % | Single analysis only - Not certified | Neutron activation analyses | |
Terbium (Tb)
|
[7440-27-9] | <0,00000977 | % | Single analysis only - Not certified | Neutron activation analyses | |
Thorium (Th)
|
[7440-29-1] | 0,0113 | % | Single analysis only - Not certified | Neutron activation analyses | |
Tungsten (W)
|
[7440-33-7] | 0,000143 | % | Single analysis only - Not certified | Neutron activation analyses | |
Uranium (U)
|
[7440-61-1] | 0,00126 | % | Single analysis only - Not certified | Neutron activation analyses | |
Zinc (Zn)
|
[7440-66-6] | 0,001 | % | Single analysis only - Not certified | Neutron activation analyses | |
Silver (Ag)
|
[7440-22-4] | <0,0001 | % | Single analysis only - Not certified | Neutron activation analyses | |
Iron (Fe)
|
[7439-89-6] | 15,83 | % | Indicative value | Fusion / XRF | |
SiO2
|
n/a | 14,58 | % | Indicative value | Fusion / XRF | |
Al2O3
|
n/a | 40,16 | % | Indicative value | Fusion / XRF | |
TiO2
|
n/a | 1,45 | % | Indicative value | Fusion / XRF | |
MnO
|
n/a | 0,02 | % | Indicative value | Fusion / XRF | |
CaO
|
n/a | -0,01 | % | Indicative value | Fusion / XRF | |
Phosphorus (P)
|
[7723-14-0] | 0,016 | % | Indicative value | Fusion / XRF | |
Sulfur (S)
|
[7704-34-9] | 0,071 | % | Indicative value | Fusion / XRF | |
MgO
|
[1309-48-4] | 0,01 | % | Indicative value | Fusion / XRF | |
K2O
|
n/a | 0,15 | % | Indicative value | Fusion / XRF | |
Na2O
|
n/a | 0,01 | % | Indicative value | Fusion / XRF | |
Loss on Ignition (L.O.I.) (1000 °C)
|
n/a | 20,86 | % | Indicative value |
Reference Material CoA specimen: for the current lot, please contact your customer service representative at info@labmix24.com
View all available product details e.g. description, analytes/parameters, CAS Number, concentrations/values, sales unit/product format, method, source, transport information