Certified values: Results are based on samples that were dried for one hour at 105°C. The values were generally derived from various fusions and acid digestion methods followed by inductively coupled plasma - optical emission spectroscopy or X-ray fluorescence
Contents
Analyte
CAS Number
Concentration
Unit
Additional information
Method
CaO
0,975
%
Certified value, non acid digestion
Cr2O3
0,0224
%
Certified value
Iron (Fe)
[7439-89-6]
65,66
%
Certified value, various titrimetric methods
Iron (Fe)
[7439-89-6]
65,62
%
Certified value, various fusions followed by X-ray fluorescence or inductively coupled plasma -optical emission spectroscopy
FeO
20,76
%
Certified value, various titrimetric methods
Loss on Ignition (LOI)
0,863
%
Certified value, at 1000 to 1050°C or by thermogravimetry
MgO
[1309-48-4]
1,043
%
Certified value, non acid digestion
MnO
0,472
%
Certified value
Phosphorus (P)
[7723-14-0]
0,012
%
Certified value
SiO2
2,633
%
Certified value
TiO2
0,0429
%
Certified value
Al2O3
0,184
%
Provisional value
Cobalt (Co)
[7440-48-4]
19,99
µg/g
Provisional value
Molybdenum (Mo)
[7439-98-7]
22,89
µg/g
Provisional value
Sulfur (S)
[7704-34-9]
0,00657
%
Provisional value, data was derived from both combustion - infrared spectrometry and fusion X-ray fluorescence
Strontium (Sr)
[7440-24-6]
4,38
µg/g
Provisional value
Vanadium (V)
[7440-62-2]
40,8
µg/g
Provisional value
Barium (Ba)
[7440-39-3]
30
µg/g
Indicative value
Carbon (C)
[7440-44-0]
0,9
%
Indicative value
CaO
0,9
%
Indicative value, digestion using various combinations of acids
Cerium (Ce)
[7440-45-1]
14
µg/g
Indicative value
Chlorine (Cl)
[7782-50-5]
0,003
%
Indicative value, data was generally derived from fusion followed by X-ray fluorescence
CO2
3
%
Indicative value
Copper (Cu)
[7440-50-8]
8
µg/g
Indicative value, data was derived using saturation magnetization analyzer
AnalyteIron (Fe)CAS Number[7439-89-6]Concentration65,66Unit%Additional informationCertified value, various titrimetric methodsMethod
AnalyteIron (Fe)CAS Number[7439-89-6]Concentration65,62Unit%Additional informationCertified value, various fusions followed by X-ray fluorescence or inductively coupled plasma -optical emission spectroscopyMethod
AnalyteFeOCAS NumberConcentration20,76Unit%Additional informationCertified value, various titrimetric methodsMethod
AnalyteLoss on Ignition (LOI)CAS NumberConcentration0,863Unit%Additional informationCertified value, at 1000 to 1050°C or by thermogravimetryMethod
AnalyteMgOCAS Number[1309-48-4]Concentration1,043Unit%Additional informationCertified value, non acid digestionMethod
AnalyteSulfur (S)CAS Number[7704-34-9]Concentration0,00657Unit%Additional informationProvisional value, data was derived from both combustion - infrared spectrometry and fusion X-ray fluorescenceMethod
AnalyteChlorine (Cl)CAS Number[7782-50-5]Concentration0,003Unit%Additional informationIndicative value, data was generally derived from fusion followed by X-ray fluorescenceMethod
AnalyteCopper (Cu)CAS Number[7440-50-8]Concentration8Unitµg/gAdditional informationIndicative value, data was derived using saturation magnetization analyzerMethod
View all available product details e.g. description, analytes/parameters, CAS Number, concentrations/values, sales unit/product format, method, source, transport information