Item no.
CRPG-AL-I
Unit
20 g
Shipment details
No Dangerous Good /not restricted
Analyte | CAS Number | Concentration | Unit | Additional information | Method |
---|---|---|---|---|---|
SiO2
|
69,34 | % | |||
Al2O3
|
18,59 | % | |||
Fe2O3
|
0,03 | % | |||
FeO
|
0,04 | % | |||
MnO
|
0,004 | % | |||
MgO
|
[1309-48-4] | 0,035 | % | ||
CaO
|
0,384 | % | |||
Na2O
|
10,59 | % | |||
K2O
|
0,14 | % | |||
TiO2
|
0,012 | % | |||
P2O5
|
0,038 | % | |||
H2O+
|
0,29 | % | |||
H2O-
|
0,06 | % | |||
CO2
|
0,2 | % | |||
Fe2O3 total
|
0,075 | % | |||
Loss on Ignition (LOI)
|
0,4 | % | proposed value | ||
Arsenic (As)
|
[7440-38-2] | 0,8 | µg/g | ||
Barium (Ba)
|
[7440-39-3] | 85 | µg/g | ||
Beryllium (Be)
|
[7440-41-7] | 2,7 | µg/g | ||
Bismuth (Bi)
|
[7440-69-9] | 0,03 | µg/g | proposed value | |
Cadmium (Cd)
|
[7440-43-9] | 0,03 | µg/g | proposed value | |
Cerium (Ce)
|
[7440-45-1] | 21 | µg/g | ||
Chlorine (Cl)
|
[7782-50-5] | 110 | µg/g | proposed value | |
Cobalt (Co)
|
[7440-48-4] | 0,2 | µg/g | ||
Chromium (Cr)
|
[7440-47-3] | 2 | µg/g | ||
Caesium (Cs)
|
[7440-46-2] | 0,34 | µg/g | ||
Copper (Cu)
|
[7440-50-8] | 3 | µg/g | ||
Dysprosium (Dy)
|
[7429-91-6] | 1,5 | µg/g | ||
Erbium (Er)
|
[7440-52-0] | 0,6 | µg/g | ||
Europium (Eu)
|
[7440-53-1] | 0,19 | µg/g | ||
Fluorine (F)
|
[7782-41-4] | 45 | µg/g | ||
Gallium (Ga)
|
[7440-55-3] | 20 | µg/g | ||
Gadolinium (Gd)
|
[7440-54-2] | 1,9 | µg/g | ||
Germanium (Ge)
|
[7440-56-4] | 1,4 | µg/g | proposed value | |
Hafnium (Hf)
|
[7440-58-6] | 2,6 | µg/g | ||
Holmium (Ho)
|
[7440-60-0] | 0,28 | µg/g | ||
Indium (In)
|
[7440-74-6] | 0,01 | µg/g | proposed value | |
Lanthanum (La)
|
[7439-91-0] | 9,5 | µg/g | ||
Lithium (Li)
|
[7439-93-2] | 1 | µg/g | ||
Lutetium (Lu)
|
[7439-94-3] | 0,13 | µg/g | ||
Molybdenum (Mo)
|
[7439-98-7] | 0,1 | µg/g | ||
Niobium (Nb)
|
[7440-03-1] | 1,6 | µg/g | ||
Neodymium (Nd)
|
[7440-00-8] | 10,4 | µg/g | ||
Nickel (Ni)
|
[7440-02-0] | 2 | µg/g | ||
Lead (Pb)
|
[7439-92-1] | 4,5 | µg/g | ||
Praseodymium (Pr)
|
[7440-10-0] | 2,8 | µg/g | ||
Rubidium (Rb)
|
[7440-17-7] | 5,8 | µg/g | ||
Sulfur (S)
|
[7704-34-9] | 85 | µg/g | proposed value | |
Antimony (Sb)
|
[7440-36-0] | 0,2 | µg/g | ||
Scandium (Sc)
|
[7440-20-2] | 1,75 | µg/g | ||
Samarium (Sm)
|
[7440-19-9] | 2,8 | µg/g | ||
Tin (Sn)
|
[7440-31-5] | 0,4 | µg/g | ||
Strontium (Sr)
|
[7440-24-6] | 80 | µg/g | ||
Tantalum (Ta)
|
[7440-25-7] | 1,9 | µg/g | ||
Terbium (Tb)
|
[7440-27-9] | 0,3 | µg/g | ||
Thorium (Th)
|
[7440-29-1] | 9,5 | µg/g | ||
Thallium (Tl)
|
[7440-28-0] | 0,04 | µg/g | proposed value | |
Thulium (Tm)
|
[7440-30-4] | 0,1 | µg/g | ||
Uranium (U)
|
[7440-61-1] | 5,8 | µg/g | ||
Vanadium (V)
|
[7440-62-2] | 2 | µg/g | ||
Tungsten (W)
|
[7440-33-7] | 0,2 | µg/g | ||
Yttrium (Y)
|
[7440-65-5] | 6,8 | µg/g | ||
Ytterbium (Yb)
|
[7440-64-4] | 0,7 | µg/g | ||
Zinc (Zn)
|
[7440-66-6] | 6 | µg/g | ||
Zirconium (Zr)
|
[7440-67-7] | 40 | µg/g |
Reference Material CoA specimen: for the current lot, please contact your customer service representative at info@labmix24.com
View all available product details e.g. description, analytes/parameters, CAS Number, concentrations/values, sales unit/product format, method, source, transport information