Pellet for LA-ICP-MS and LIBS application /// The principle behind LA-ICP-MS (Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry) involves a laser beam removing (ablating) material from a sample and analysing its chemical composition in a mass spectrometer /// LIBS (Laser-Induced Breakdown Spectroscopy) uses a laser beam to interact with the sample. Due to the extreme heat of the laser (10,000 K and more) a plasma is formed. A plasma is a cloud of ions (charged atoms) and electrons (negatively charged particles). When this plasma collapses it emits light. Light is a mixture of different wavelengths. This light is then transferred through a fiberoptic cable to a spectrometer, which can precisely split the light into its respective wavelengths. The working principle of the LIBS-spectrometer is similar to a prism as it disperses the incomming light. Each element has several characteristic wavelengths. A detector is able to attribute an intensity to each of them.
Inhalte
Analyt
CAS-Nummer
Konzentration
Einheit
Zusätzliche Informationen
Methode
Na2O
0,1 ± 0,04
g/100g
MgO
[1309-48-4]
35,21 ± 0,18
g/100g
Al2O3
2,9 ± 0,08
g/100g
SiO2
39,43 ± 0,15
g/100g
P2O5
0,04 ± 0,02
g/100g
K2O
0,02 ± 0,01
g/100g
CaO
1,2 ± 0,03
g/100g
TiO2
0,11 ± 0,01
g/100g
MnO
0,12 ± 0,01
g/100g
Fe2O3(T)
8,34 ± 0,1
g/100g
Lithium (Li)
[7439-93-2]
27 ± 3
g/100g
Boron (B)
[7440-42-8]
140 ± 12
g/100g
Chlorine (Cl)
[7782-50-5]
800 ± 200
g/100g
Scandium (Sc)
[7440-20-2]
13 ± 0,7
g/100g
Vanadium (V)
[7440-62-2]
75 ± 9
g/100g
Chromium (Cr)
[7440-47-3]
2300 ± 100
g/100g
Cobalt (Co)
[7440-48-4]
100 ± 12
g/100g
Nickel (Ni)
[7440-02-0]
2000 ± 80
g/100g
Copper (Cu)
[7440-50-8]
28 ± 3
g/100g
Zinc (Zn)
[7440-66-6]
85 ± 7
g/100g
Gallium (Ga)
[7440-55-3]
3 ± 0,5
g/100g
Arsenic (As)
[7440-38-2]
10 ± 2
g/100g
Rubidium (Rb)
[7440-17-7]
4 ± 2
g/100g
Strontium (Sr)
[7440-24-6]
9 ± 1,85
g/100g
Yttrium (Y)
[7440-65-5]
2,5 ± 0,2
g/100g
Zirconium (Zr)
[7440-67-7]
4 ± 1
g/100g
Molybdenum (Mo)
[7439-98-7]
0,55 ± 0,1
g/100g
Caesium (Cs)
[7440-46-2]
10 ± 0,9
g/100g
Barium (Ba)
[7440-39-3]
27 ± 3
g/100g
Lanthanum (La)
[7439-91-0]
0,35 ± 0,07
g/100g
Cerium (Ce)
[7440-45-1]
0,8 ± 0,1
g/100g
Praseodymium (Pr)
[7440-10-0]
0,12 ± 0,01
g/100g
Neodymium (Nd)
[7440-00-8]
0,6 ± 0,04
g/100g
Samarium (Sm)
[7440-19-9]
0,2 ± 0,01
g/100g
Europium (Eu)
[7440-53-1]
0,08 ± 0,01
g/100g
Gadolinium (Gd)
[7440-54-2]
0,3 ± 0,03
g/100g
Terbium (Tb)
[7440-27-9]
0,06 ± 0,01
g/100g
Dysprosium (Dy)
[7429-91-6]
0,38 ± 0,03
g/100g
Holmium (Ho)
[7440-60-0]
0,09 ± 0,01
g/100g
Erbium (Er)
[7440-52-0]
0,28 ± 0,02
g/100g
Thulium (Tm)
[7440-30-4]
0,045 ± 0,01
g/100g
Ytterbium (Yb)
[7440-64-4]
0,28 ± 0,02
g/100g
Lutetium (Lu)
[7439-94-3]
0,045 ± 0,005
g/100g
Tantalum (Ta)
[7440-25-7]
0,02 ± 0,005
g/100g
Tungsten (W)
[7440-33-7]
20 ± 7
g/100g
Lead (Pb)
[7439-92-1]
13 ± 3
g/100g
Weiteres
Zertifikatmuster
Muster-CoA des Referenzmaterials: für die aktuelle Charge kontaktieren Sie unseren Kundendienst unter info@labmix24.com
Produktdatenblatt
Alle Details zum Produkt z.B. Analyte/Parameter, CAS-Nummer, Konzentration/Wert, Einheit/Format, Methode, Quelle…
Die myStandards GmbH ist ein deutsches Unternehmen mit Sitz in Kiel. Es wurde 2018 gegründet und ist seitdem Vorreiter in der Entwicklung und Herstellung von (zertifizierten) Referenzmaterialien für die geochemische Feststoffanalytik mit Analysemethoden wie LA-ICP-MS, µXRF, XRF und LIBS. Mit Hilfe eines selbstentwickelten, hoch technologisiertem Verfahren stellt myStandards sehr reine, bindemittelfreie und ultrahomogene Presstabletten aus nano-partikulärem Pulver her.
Zu den Materialklassen und Produkten, die aktuell im Portfolio sind, gehören: