Elements and Oxides determined as follows: Multi-element Iron Ore Suite - XRF fused disc analysis /// Loss on Ignition - Thermo Gravimetric Analysis
Inhalte
Analyt
CAS-Nummer
Konzentration
Einheit
Zusätzliche Informationen
Methode
Iron (Fe)
[7439-89-6]
52,78
%
Corrected for moisture according to ISO2596:2006
Iron (Fe) calculated
52,75
%
Corrected for moisture according to ISO2596:2006
SiO2
11,99
%
Corrected for moisture according to ISO2596:2006
Al2O3
3,09
%
Corrected for moisture according to ISO2596:2006
TiO2
0,193
%
Corrected for moisture according to ISO2596:2006
CaO
0,067
%
Corrected for moisture according to ISO2596:2006
K2O
0,032
%
Corrected for moisture according to ISO2596:2006
MgO
[1309-48-4]
0,175
%
Corrected for moisture according to ISO2596:2006
Manganese (Mn)
[7439-96-5]
0,134
%
Corrected for moisture according to ISO2596:2006
Phosphorus (P)
[7723-14-0]
0,042
%
Corrected for moisture according to ISO2596:2006
Sulfur (S)
[7704-34-9]
0,021
%
Corrected for moisture according to ISO2596:2006
Loss on Ignition (L.O.I.) (371 °C)
7,52
%
Corrected for moisture according to ISO2596:2006
Loss on Ignition (L.O.I.) (425 °C)
7,79
%
Corrected for moisture according to ISO2596:2006
Loss on Ignition (L.O.I.) (650 °C)
8,38
%
Corrected for moisture according to ISO2596:2006
Loss on Ignition (L.O.I.) (1000 °C)
8,55
%
Corrected for moisture according to ISO2596:2006
Arsenic (As)
[7440-38-2]
0,014
%
Corrected for moisture according to ISO2596:2006
Chlorine (Cl)
[7782-50-5]
0,004
%
Corrected for moisture according to ISO2596:2006
Cobalt (Co)
[7440-48-4]
0,001
%
Corrected for moisture according to ISO2596:2006
Copper (Cu)
[7440-50-8]
0,001
%
Corrected for moisture according to ISO2596:2006
Lead (Pb)
[7439-92-1]
0,004
%
Corrected for moisture according to ISO2596:2006
Zinc (Zn)
[7440-66-6]
0,007
%
Corrected for moisture according to ISO2596:2006
Barium (Ba)
[7440-39-3]
0,002
%
Corrected for moisture according to ISO2596:2006
Chromium (Cr)
[7440-47-3]
0,009
%
Corrected for moisture according to ISO2596:2006
Nickel (Ni)
[7440-02-0]
0,003
%
Corrected for moisture according to ISO2596:2006
Tin (Sn)
[7440-31-5]
0,001
%
Corrected for moisture according to ISO2596:2006
Strontium (Sr)
[7440-24-6]
-
%
Corrected for moisture according to ISO2596:2006
Vanadium (V)
[7440-62-2]
0,003
%
Corrected for moisture according to ISO2596:2006
Zirconium (Zr)
[7440-67-7]
0,019
%
Corrected for moisture according to ISO2596:2006
Iron (Fe)
[7439-89-6]
52,66
%
Drying to constant mass
Iron (Fe) calculated
52,63
%
Drying to constant mass
SiO2
11,82
%
Drying to constant mass
Al2O3
3,05
%
Drying to constant mass
TiO2
0,194
%
Drying to constant mass
CaO
0,063
%
Drying to constant mass
K2O
0,031
%
Drying to constant mass
MgO
[1309-48-4]
0,172
%
Drying to constant mass
Manganese (Mn)
[7439-96-5]
0,133
%
Drying to constant mass
Phosphorus (P)
[7723-14-0]
0,043
%
Drying to constant mass
Sulfur (S)
[7704-34-9]
0,021
%
Drying to constant mass
Loss on Ignition (L.O.I.) (371 °C)
7,81
%
Drying to constant mass
Loss on Ignition (L.O.I.) (425 °C)
8,14
%
Drying to constant mass
Loss on Ignition (L.O.I.) (650 °C)
8,67
%
Drying to constant mass
Loss on Ignition (L.O.I.) (1000 °C)
8,82
%
Drying to constant mass
Arsenic (As)
[7440-38-2]
0,014
%
Drying to constant mass
Chlorine (Cl)
[7782-50-5]
0,006
%
Drying to constant mass
Cobalt (Co)
[7440-48-4]
0,001
%
Drying to constant mass
Copper (Cu)
[7440-50-8]
0,001
%
Drying to constant mass
Lead (Pb)
[7439-92-1]
0,005
%
Drying to constant mass
Zinc (Zn)
[7440-66-6]
0,009
%
Drying to constant mass
Barium (Ba)
[7440-39-3]
-
%
Drying to constant mass
Chromium (Cr)
[7440-47-3]
0,011
%
Drying to constant mass
Nickel (Ni)
[7440-02-0]
0,004
%
Drying to constant mass
Tin (Sn)
[7440-31-5]
0,002
%
Drying to constant mass
Strontium (Sr)
[7440-24-6]
0,001
%
Drying to constant mass
Vanadium (V)
[7440-62-2]
0,003
%
Drying to constant mass
Zirconium (Zr)
[7440-67-7]
0,021
%
Drying to constant mass
AnalytIron (Fe) calculatedCAS-NummerKonzentration52,75Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytSiO2CAS-NummerKonzentration11,99Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytAl2O3CAS-NummerKonzentration3,09Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytTiO2CAS-NummerKonzentration0,193Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytCaOCAS-NummerKonzentration0,067Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytK2OCAS-NummerKonzentration0,032Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytMgOCAS-Nummer[1309-48-4]Konzentration0,175Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytManganese (Mn)CAS-Nummer[7439-96-5]Konzentration0,134Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytPhosphorus (P)CAS-Nummer[7723-14-0]Konzentration0,042Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytSulfur (S)CAS-Nummer[7704-34-9]Konzentration0,021Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytLoss on Ignition (L.O.I.) (371 °C)CAS-NummerKonzentration7,52Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytLoss on Ignition (L.O.I.) (425 °C)CAS-NummerKonzentration7,79Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytLoss on Ignition (L.O.I.) (650 °C)CAS-NummerKonzentration8,38Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytLoss on Ignition (L.O.I.) (1000 °C)CAS-NummerKonzentration8,55Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytArsenic (As)CAS-Nummer[7440-38-2]Konzentration0,014Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytChlorine (Cl)CAS-Nummer[7782-50-5]Konzentration0,004Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytCobalt (Co)CAS-Nummer[7440-48-4]Konzentration0,001Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytCopper (Cu)CAS-Nummer[7440-50-8]Konzentration0,001Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytLead (Pb)CAS-Nummer[7439-92-1]Konzentration0,004Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytZinc (Zn)CAS-Nummer[7440-66-6]Konzentration0,007Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytBarium (Ba)CAS-Nummer[7440-39-3]Konzentration0,002Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytChromium (Cr)CAS-Nummer[7440-47-3]Konzentration0,009Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytNickel (Ni)CAS-Nummer[7440-02-0]Konzentration0,003Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytTin (Sn)CAS-Nummer[7440-31-5]Konzentration0,001Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytStrontium (Sr)CAS-Nummer[7440-24-6]Konzentration-Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytVanadium (V)CAS-Nummer[7440-62-2]Konzentration0,003Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytZirconium (Zr)CAS-Nummer[7440-67-7]Konzentration0,019Einheit%Zusätzliche InformationenCorrected for moisture according to ISO2596:2006Methode
AnalytIron (Fe)CAS-Nummer[7439-89-6]Konzentration52,66Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytIron (Fe) calculatedCAS-NummerKonzentration52,63Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytSiO2CAS-NummerKonzentration11,82Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytAl2O3CAS-NummerKonzentration3,05Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytTiO2CAS-NummerKonzentration0,194Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytCaOCAS-NummerKonzentration0,063Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytK2OCAS-NummerKonzentration0,031Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytMgOCAS-Nummer[1309-48-4]Konzentration0,172Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytManganese (Mn)CAS-Nummer[7439-96-5]Konzentration0,133Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytPhosphorus (P)CAS-Nummer[7723-14-0]Konzentration0,043Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytSulfur (S)CAS-Nummer[7704-34-9]Konzentration0,021Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytLoss on Ignition (L.O.I.) (371 °C)CAS-NummerKonzentration7,81Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytLoss on Ignition (L.O.I.) (425 °C)CAS-NummerKonzentration8,14Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytLoss on Ignition (L.O.I.) (650 °C)CAS-NummerKonzentration8,67Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytLoss on Ignition (L.O.I.) (1000 °C)CAS-NummerKonzentration8,82Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytArsenic (As)CAS-Nummer[7440-38-2]Konzentration0,014Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytChlorine (Cl)CAS-Nummer[7782-50-5]Konzentration0,006Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytCobalt (Co)CAS-Nummer[7440-48-4]Konzentration0,001Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytCopper (Cu)CAS-Nummer[7440-50-8]Konzentration0,001Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytLead (Pb)CAS-Nummer[7439-92-1]Konzentration0,005Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytZinc (Zn)CAS-Nummer[7440-66-6]Konzentration0,009Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytBarium (Ba)CAS-Nummer[7440-39-3]Konzentration-Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytChromium (Cr)CAS-Nummer[7440-47-3]Konzentration0,011Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytNickel (Ni)CAS-Nummer[7440-02-0]Konzentration0,004Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytTin (Sn)CAS-Nummer[7440-31-5]Konzentration0,002Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytStrontium (Sr)CAS-Nummer[7440-24-6]Konzentration0,001Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytVanadium (V)CAS-Nummer[7440-62-2]Konzentration0,003Einheit%Zusätzliche InformationenDrying to constant massMethode
AnalytZirconium (Zr)CAS-Nummer[7440-67-7]Konzentration0,021Einheit%Zusätzliche InformationenDrying to constant massMethode
Weiteres
Zertifikatmuster
Muster-CoA des Referenzmaterials: für die aktuelle Charge kontaktieren Sie unseren Kundendienst unter info@labmix24.com